Furnaces, AC and heat pumps

How old is my Coleman or Evcon furnace, AC or heat pump?


Coleman and Evcon heating and cooling equipment is a York-family line and shares York's letter-digit serial since October 2004. Coleman's all-digit serials changed in April 1992: before that date the first two digits are the month, after it they are the year. The decoder shows whichever readings fit.

Appliance Age Decoder
Serial numbers · build dates · real answers
Try an example:
Free · no sign-up · runs in your browser
Made September 2005
Your furnace is about 21 years old.
Past its typical lifespanA furnace typically lasts 15 to 20 years. Plan to replace it soon rather than wait for a breakdown.
NewTypical life 15 to 20 years30+

Condition matters more than the calendar. Rust, leaks, strange noises, rising bills or repeated repairs are reasons to act sooner. A clean, quiet, well-kept unit can outlast the range.

Read as: letter, digit, letter, digit.

Warranty: Coleman covers parts for 10 years if the unit was registered within 90 days of installation, or 5 years if not. At about 21 years, the standard parts warranty has likely run out. Heat exchangers carry 20 years, or lifetime on registered Echelon and LX furnaces. Check yours.

Get free local pricing on heating and cooling replacement

Call (213) 953-5723

Free call. You will be asked for your 5-digit ZIP code, then connected to a local company. Stay on the line, because it can take a few seconds to connect. The company that answers is an independent partner, and this site may be paid a fee for the call. You are never obliged to hire anyone.

Coleman at a glance

Where the date isLetter, digit, letter, digit (October 2004 to today), plus 3 older or rarer styles
How sureEvery style checked against two or more sources
Typical lifeFurnace 15 to 20 years; central air conditioner 12 to 15 years; heat pump 10 to 15 years
Made byJC Residential and Light Commercial, a Bosch company
Parts warranty10 years if registered within 90 days of installation; 5 if not
Recalls2 CPSC notices since 2000 (see below)

Worked examples

Here is how the rule reads on sample serials in each style. Your own serial will have different digits in the same positions.

Serial W0K5896070
  1. Identify the style: letter, digit, letter, digit (October 2004 to today).
  2. Apply the rule: The first letter is the plant. The second and fourth characters together are the year. The third character is the month letter (A is January through H, then K is September, L October, M November, N December).
  3. Result: built September 2005.
  4. Age as of November 2026: about 21 years old. A furnace typically lasts 15 to 20 years, so the verdict is: past its typical lifespan.
Serial WAKM011379
  1. Identify the style: four letters, then six digits (1971 to October 2004).
  2. Apply the rule: The second letter is the month and the third letter is the year. The year letters repeat every 21 years, so one letter can mean two years.
  3. Result: built January 2001.
  4. Age as of November 2026: about 25 years old. A furnace typically lasts 15 to 20 years, so the verdict is: past its typical lifespan.
Serial 990697368
  1. Identify the style: all digits, year then month (April 1992 to 2004).
  2. Apply the rule: From April 1992 the first two digits are the year and the next two are the month.
  3. Result: built June 1999.
  4. Age as of November 2026: about 27 years old. A furnace typically lasts 15 to 20 years, so the verdict is: past its typical lifespan.
Serial 0188123456
  1. Identify the style: all digits, month then year (before April 1992).
  2. Apply the rule: Before April 1992 the first two digits are the month and the next two are the year.
  3. Result: built January 1988.
  4. Age as of November 2026: about 38 years old. A furnace typically lasts 15 to 20 years, so the verdict is: past its typical lifespan.

How to read a Coleman serial number

Letter, digit, letter, digit (October 2004 to today)

The first letter is the plant. The second and fourth characters together are the year. The third character is the month letter (A is January through H, then K is September, L October, M November, N December).

W0K5896070 reads as September 2005.

Month letters
LetterMonthLetterMonth
AJanuaryGJuly
BFebruaryHAugust
CMarchKSeptember
DAprilLOctober
EMayMNovember
FJuneNDecember

Two sources agree Building Intelligence Center, PickHVAC, Waypoint Property Inspection, Energy Trust of Oregon furnace chart

Four letters, then six digits (1971 to October 2004)

The second letter is the month and the third letter is the year. The year letters repeat every 21 years, so one letter can mean two years.

WAKM011379 reads as January 2001.

One source reads M as December on this style; three others read M as November and N as December, which is used here.

This maker reused its year letters after 21 years. Check the plate's ANSI year or the refrigerant type to pick the right one.

Year letters for four letters, then six digits
LetterYearLetterYear
A1971, 1992B1972, 1993
C1973, 1994D1974, 1995
E1975, 1996F1976, 1997
G1977, 1998H1978, 1999
J1979, 2000K1980, 2001
L1981, 2002M1982, 2003
N1983, 2004P1984
R1985S1986
T1987V1988
W1989X1990
Y1991

Two sources agree Building Intelligence Center, PickHVAC, Waypoint Property Inspection, Energy Trust of Oregon furnace chart, GPI furnace age chart

All digits, year then month (April 1992 to 2004)

From April 1992 the first two digits are the year and the next two are the month.

990697368 reads as June 1999.

Two sources agree Building Intelligence Center, InterNACHI inspector forum, InspectAPedia, GPI furnace age chart

All digits, month then year (before April 1992)

Before April 1992 the first two digits are the month and the next two are the year.

0188123456 reads as January 1988.

Two sources agree Building Intelligence Center, InterNACHI inspector forum, InspectAPedia, GPI furnace age chart

Mistakes to avoid

  • Confusing Coleman heating and cooling with Coleman RV air conditioners or camping gear, which are different companies with different codes.

Model number or serial number?

The model number describes the unit; the serial dates it. Coleman's Echelon AC21 air conditioners run from AC21B24 to AC21B60, covering 2 to 5 tons, so the last two digits are the size in thousands of Btu per hour. Coleman doesn't publish a full key.

Model numberWhat it tells you
AC21B36Echelon variable-capacity air conditioner in the AC21B24 to AC21B60 range; 36 = 36,000 Btu/h (3 tons)

Who makes Coleman

Coleman heating and cooling equipment belongs to the York family of brands, which Bosch Home Comfort Group has run since July 31, 2025; Coleman's site names JC Residential and Light Commercial LLC and says the Coleman name is used under license from The Coleman Company, Inc. Its sister brands are York, Luxaire, Fraser-Johnston and Champion.

Coleman warranty

Register a Coleman online within 90 days of installation and parts are covered for 10 years; otherwise 5. Registered Echelon air conditioners and heat pumps get a lifetime compressor warranty, which drops to 5 or 10 years without registration. Registered Echelon and LX gas furnaces get a lifetime heat exchanger warranty (20 years on the TL9E and TL8E), and 20 years without registration. California and Quebec don't require registration.

These are Coleman's current terms. Terms change over the years, and the one that applies to you is the warranty in force when your unit was installed.

Check your warranty on Coleman's warranty lookup. Have the model and serial numbers ready.

Coleman recalls

These U.S. Consumer Product Safety Commission notices since 2000 name Coleman furnaces, central air conditioners or heat pumps. Most cover only certain models or build dates, so compare your model and serial with the notice before you worry.

Room, window and hotel units, dehumidifiers and boilers are not part of this check. Check cpsc.gov/Recalls for those and for anything newer.

Coleman furnace

Typical life: 15 to 20 years

A gas furnace usually lasts 15 to 20 years. Well-maintained units in mild climates reach 25; units that run hard with dirty filters fail sooner.

Where the serial is: Inside the front panel or on the side of the cabinet. Take the lower door off if you have to; the label is usually on the blower door or inside wall.

How long does a furnace last? · How to tell how old your furnace is · How much does a new furnace cost, and is a repair worth it?

Furnace with its serial number label circled

Coleman central air conditioner

Typical life: 12 to 15 years

A central AC condenser usually lasts 12 to 15 years. In hot climates where it runs most of the year, 10 is more typical; in the north, 20 is possible.

Where the serial is: On the data plate on the outdoor unit, usually near the electrical and refrigerant connections.

How long does a central air conditioner last? · How to tell how old your AC or heat pump is · What an AC or heat pump replacement costs, and when repair still wins

Outdoor AC unit with its serial number label circled

Coleman heat pump

Typical life: 10 to 15 years

An air-source heat pump usually lasts 10 to 15 years. It runs in both seasons, so it logs more hours than a furnace or an AC alone.

Where the serial is: On the data plate on the outdoor unit, near the line connections.

How long does a heat pump last? · How to tell how old your AC or heat pump is · What an AC or heat pump replacement costs, and when repair still wins

Outdoor heat pump with its serial number label circled

What refrigerant is in a Coleman AC or heat pump?

The data plate on the outdoor unit names the refrigerant. If the plate is faded, the build year narrows it down.

BuiltUsuallyWhat it means
Before 2010R-22 or R-410AFrom 2010 R-22 could no longer go into new equipment, and new R-22 production ended in 2020. Refills now come from recovered stock and cost more, but repairs are still allowed.
2010 to 2024R-410AParts and refrigerant are easy to find. Units built before 2025 can still be installed new until stock runs out, under an EPA rule that took effect July 27, 2026.
2025 onA newer, lower-warming refrigerantNew systems built from January 1, 2025 moved to lower-warming refrigerants. The plate names which one.

Trust the plate over this table. If yours uses R-22, read what an old R-22 system means now.

Questions

Where is the serial number on a Coleman furnace?

Inside the front panel or on the side of the cabinet. Take the lower door off if you have to; the label is usually on the blower door or inside wall. Use the line marked Serial No. or S/N, not Model No.

Where is the serial number on a Coleman central air conditioner?

On the data plate on the outdoor unit, usually near the electrical and refrigerant connections. Use the line marked Serial No. or S/N, not Model No.

Where is the serial number on a Coleman heat pump?

On the data plate on the outdoor unit, near the line connections. Use the line marked Serial No. or S/N, not Model No.

How sure is the date for a Coleman?

The Coleman rule on this page is confirmed by at least two independent sources. If the plate prints a manufacture date, that beats any decoded date.

How do I know which Coleman serial style I have?

Look at the shape of the serial. Letter, digit, letter, digit (October 2004 to today), for example W0K5896070; Four letters, then six digits (1971 to October 2004), for example WAKM011379; All digits, year then month (April 1992 to 2004), for example 990697368; All digits, month then year (before April 1992), for example 0188123456. The decoder tests every style and shows each reading that fits.

Why does the decoder show more than one year for my Coleman?

This maker reused its year letters after 21 years. Check the plate's ANSI year or the refrigerant type to pick the right one.

How long does a Coleman furnace last?

A typical furnace lasts 15 to 20 years. Upkeep, climate and how hard the unit works matter more than the brand.

Is my Coleman still under warranty?

If it was registered within 90 days of installation, a Coleman has 10 years on parts; if not, 5. Registered Echelon units and some furnaces carry lifetime compressor or heat exchanger terms. Coleman's warranty lookup checks registered units on its Warranty Lookup tab.

How do I find the size of my Coleman AC from the model number?

On Coleman's AC21 series the last two digits give the size in thousands of Btu per hour: AC21B24 is 2 tons and AC21B60 is 5 tons.

Has Coleman had recalls?

Yes. CPSC lists 2 recalls since 2000 that name Coleman furnaces, central air conditioners or heat pumps. Most cover specific models or build dates, so check the model and serial against each notice listed on this page.

Sources

  1. Building Intelligence Center
  2. PickHVAC
  3. Waypoint Property Inspection
  4. Energy Trust of Oregon furnace chart
  5. GPI furnace age chart
  6. InterNACHI inspector forum
  7. InspectAPedia
  8. Coleman AC21 variable-capacity air conditioner
  9. Bosch Home Comfort Group: North and Latin America brands
  10. ACHR News, Aug 1 2025: Bosch closes JCI HVAC deal
  11. Coleman product warranties and registration
  12. Coleman warranties
  13. Johnson Controls product registration and warranty lookup
  14. CPSC: Coleman, Coleman Evcon and Red T gas furnaces for manufactured homes (fire hazard)
  15. CPSC: York, Luxaire and Coleman gas furnaces
  16. EPA: What technicians and contractors need to know about phasing out HCFC refrigerants
  17. Contracting Business: EPA revises refrigerant rules, ends R-410A installation deadline
  18. NAHB: EPA finalizes refrigerant rule update to allow older HVAC unit installation

Serial rules last checked against their sources October 19, 2026. Warranty, model and recall details checked November 16, 2026. Found a date that doesn't match your label? Tell us.

Keep a record of your home

The age you just looked up is the kind of fact that gets lost. A written record of serial numbers, install dates, repairs and who did the work saves the next owner, inspector or insurer from guessing.

Cover of Keep This With the House

Keep This With the House

A lifetime logbook for the house, organized by system, with room for serial numbers, install dates, repairs and contractors.

Paperback on Amazon

Cover of The House Has Old Pipes

The House Has Old Pipes

Galvanized, polybutylene, cast iron and the sewer line: what fails, what it costs and how to decide.

Paperback on Amazon · Kindle on Amazon

Cover of The House Is Fifty Years Old

The House Is Fifty Years Old

A buyer's guide to older homes: wiring, pipes, lead, asbestos, insurance refusals and what the repairs cost.

Paperback on Amazon · Kindle on Amazon

Book links are Amazon affiliate links.