How old is my Armstrong Air, AirEase, Concord or Allied furnace, AC or heat pump?
Armstrong Air, AirEase, Concord and Allied are Lennox brands, and their serials since the early 1990s use the Lennox pattern: plant code, year, month letter. Ten-digit all-number serials from the 1990s and 2000s put the year in the seventh and eighth digits. A much older shape from 1978 to 1992 is read differently by different sources, so treat that result as rough.

Condition matters more than the calendar. Rust, leaks, strange noises, rising bills or repeated repairs are reasons to act sooner. A clean, quiet, well-kept unit can outlast the range.
Read as: plant code, year, then month letter.
Warranty: Armstrong Air covers parts for 10 years if the unit was registered within 60 days of installation, or 5 years if not. At about 19 years, the standard parts warranty has likely run out. Heat exchangers carry a limited lifetime if registered, 20 years if not. Check yours.
Get free local pricing on heating and cooling replacement
Call (213) 953-5723Free call. You will be asked for your 5-digit ZIP code, then connected to a local company. Stay on the line, because it can take a few seconds to connect. The company that answers is an independent partner, and this site may be paid a fee for the call. You are never obliged to hire anyone.
Armstrong Air at a glance
| Where the date is | Plant code, year, then month letter (early 1990s to today), plus 2 older or rarer styles |
|---|---|
| How sure | Every style checked against two or more sources |
| Typical life | Furnace 15 to 20 years; central air conditioner 12 to 15 years; heat pump 10 to 15 years |
| Made by | Allied Air Enterprises, a Lennox International company |
| Parts warranty | 10 years if registered within 60 days of installation; 5 if not |
| Recalls | 1 CPSC notice since 2000 (see below) |
Worked examples
Here is how the rule reads on sample serials in each style. Your own serial will have different digits in the same positions.
- Identify the style: plant code, year, then month letter (early 1990s to today).
- Apply the rule: The first two digits are the factory, not the date. The next two digits are the year and the letter after them is the month (A is January, M is December, I is skipped).
- Result: built February 2007.
- Age as of November 2026: about 19 years old. A furnace typically lasts 15 to 20 years, so the verdict is: in the usual replacement window.
- Identify the style: ten digits, date at the end (1990s to 2000s).
- Apply the rule: On ten-digit all-number serials the seventh and eighth digits are the year and the last two are the week.
- Result: built week 28 of 2003.
- Age as of November 2026: about 23 years old. A furnace typically lasts 15 to 20 years, so the verdict is: past its typical lifespan.
- Identify the style: letter, five digits, three letters (1978 to 1992).
- Apply the rule: The seventh character is the month letter and the eighth is the year code (8 and 9 for 1978 and 1979, then A for 1980 through N for 1992).
- Result: built May 1983.
- Age as of November 2026: about 43 years old. A furnace typically lasts 15 to 20 years, so the verdict is: past its typical lifespan.
How to read an Armstrong Air serial number
Plant code, year, then month letter (early 1990s to today)
The first two digits are the factory, not the date. The next two digits are the year and the letter after them is the month (A is January, M is December, I is skipped).
4607B20058 reads as February 2007.
| Letter | Month | Letter | Month |
|---|---|---|---|
| A | January | G | July |
| B | February | H | August |
| C | March | J | September |
| D | April | K | October |
| E | May | L | November |
| F | June | M | December |
Two sources agree Building Intelligence Center, McGarry and Madsen Home Inspection, InterNACHI inspector forum, Energy Trust of Oregon furnace chart
Ten digits, date at the end (1990s to 2000s)
On ten-digit all-number serials the seventh and eighth digits are the year and the last two are the week.
4140720328 reads as week 28 of 2003.
Two sources agree Building Intelligence Center, McGarry and Madsen Home Inspection, Energy Trust of Oregon furnace chart, PickHVAC
Letter, five digits, three letters (1978 to 1992)
The seventh character is the month letter and the eighth is the year code (8 and 9 for 1978 and 1979, then A for 1980 through N for 1992).
A10322EDB reads as May 1983.
| Letter | Year | Letter | Year |
|---|---|---|---|
| 8 | 1978 | 9 | 1979 |
| A | 1980 | B | 1981 |
| C | 1982 | D | 1983 |
| E | 1984 | F | 1985 |
| G | 1986 | H | 1987 |
| J | 1988 | K | 1989 |
| L | 1990 | M | 1991 |
| N | 1992 |
Two sources agree InterNACHI inspector forum, McGarry and Madsen Home Inspection
Mistakes to avoid
- Reading the plant code at the front as the year.
- Treating a result from the 1978 to 1992 letter shape as exact. Sources disagree on that format.
Model number or serial number?
The model number describes the unit; the serial dates it. On Armstrong Air and other Allied Air outdoor units such as the 4SCU16LE136P, the 4 means R-410A, SCU a split air conditioner, 16 the SEER and LE the tier; then come a region digit (1) and a size code (36), and P marks 208/230 volt single phase. The size code is nominal: the 136 unit is rated about 34,000 Btu per hour, roughly 3 tons.
| Model number | What it tells you |
|---|---|
| 4SCU16LE136P | R-410A split air conditioner, 16 SEER, louvered enhanced; 1 = all regions; 36 = about 3 tons; P = 208/230 volt single phase |
Who makes Armstrong Air
Armstrong Air, AirEase, Concord and Allied are made by Allied Air Enterprises, a division of Lennox International, which also makes Ducane and MagicPak. Newer serials from all of them follow the Lennox pattern.
Armstrong Air warranty
Allied Air's warranty for Armstrong Air, AirEase and Concord units gives 5 years on parts and the compressor and 20 years on heat exchangers. Register online within 60 days of installation, or of closing on a new home, and parts and the compressor go to 10 years, with a limited lifetime on heat exchangers; the extension is for the original buyer. California and Quebec don't allow registration requirements, so owners there can register or keep the installer's invoice instead. Without proof of installation, coverage starts six months after the build date. Armstrong says the term for your unit is printed on the back cover of the installation manual.
These are Armstrong Air's current terms. Terms change over the years, and the one that applies to you is the warranty in force when your unit was installed.
Check your warranty on Armstrong Air's warranty lookup. Have the model and serial numbers ready.
Armstrong Air recalls
These U.S. Consumer Product Safety Commission notices since 2000 name Armstrong Air furnaces, central air conditioners or heat pumps. Most cover only certain models or build dates, so compare your model and serial with the notice before you worry.
- June 2023: Armstrong Air and AirEase 96% gas furnaces (carbon monoxide hazard). Single-stage models A96UH1E045B12S, A96UH1E070B12S and A96UH1E110C20S, sold September 2022 to March 2023. The model is on the label behind the furnace door.
Room, window and hotel units, dehumidifiers and boilers are not part of this check. Check cpsc.gov/Recalls for those and for anything newer.
Armstrong Air furnace
Typical life: 15 to 20 years
A gas furnace usually lasts 15 to 20 years. Well-maintained units in mild climates reach 25; units that run hard with dirty filters fail sooner.
Where the serial is: Inside the front panel or on the side of the cabinet. Take the lower door off if you have to; the label is usually on the blower door or inside wall.
How long does a furnace last? · How to tell how old your furnace is · How much does a new furnace cost, and is a repair worth it?

Armstrong Air central air conditioner
Typical life: 12 to 15 years
A central AC condenser usually lasts 12 to 15 years. In hot climates where it runs most of the year, 10 is more typical; in the north, 20 is possible.
Where the serial is: On the data plate on the outdoor unit, usually near the electrical and refrigerant connections.
How long does a central air conditioner last? · How to tell how old your AC or heat pump is · What an AC or heat pump replacement costs, and when repair still wins

Armstrong Air heat pump
Typical life: 10 to 15 years
An air-source heat pump usually lasts 10 to 15 years. It runs in both seasons, so it logs more hours than a furnace or an AC alone.
Where the serial is: On the data plate on the outdoor unit, near the line connections.
How long does a heat pump last? · How to tell how old your AC or heat pump is · What an AC or heat pump replacement costs, and when repair still wins

Armstrong Air labels: Armstrong Air says the model and serial numbers are on the front or side of the unit, and the warranty term is printed on the back cover of the installation manual.
What refrigerant is in an Armstrong Air AC or heat pump?
The data plate on the outdoor unit names the refrigerant. If the plate is faded, the build year narrows it down.
| Built | Usually | What it means |
|---|---|---|
| Before 2010 | R-22 or R-410A | From 2010 R-22 could no longer go into new equipment, and new R-22 production ended in 2020. Refills now come from recovered stock and cost more, but repairs are still allowed. |
| 2010 to 2024 | R-410A | Parts and refrigerant are easy to find. Units built before 2025 can still be installed new until stock runs out, under an EPA rule that took effect July 27, 2026. |
| 2025 on | A newer, lower-warming refrigerant | New systems built from January 1, 2025 moved to lower-warming refrigerants. The plate names which one. |
Trust the plate over this table. If yours uses R-22, read what an old R-22 system means now.
Questions
Where is the serial number on an Armstrong Air furnace?
Inside the front panel or on the side of the cabinet. Take the lower door off if you have to; the label is usually on the blower door or inside wall. Use the line marked Serial No. or S/N, not Model No.
Where is the serial number on an Armstrong Air central air conditioner?
On the data plate on the outdoor unit, usually near the electrical and refrigerant connections. Use the line marked Serial No. or S/N, not Model No.
Where is the serial number on an Armstrong Air heat pump?
On the data plate on the outdoor unit, near the line connections. Use the line marked Serial No. or S/N, not Model No.
How sure is the date for an Armstrong Air?
The Armstrong Air rule on this page is confirmed by at least two independent sources. If the plate prints a manufacture date, that beats any decoded date.
How do I know which Armstrong Air serial style I have?
Look at the shape of the serial. Plant code, year, then month letter (early 1990s to today), for example 4607B20058; Ten digits, date at the end (1990s to 2000s), for example 4140720328; Letter, five digits, three letters (1978 to 1992), for example A10322EDB. The decoder tests every style and shows each reading that fits.
How long does an Armstrong Air furnace last?
A typical furnace lasts 15 to 20 years. Upkeep, climate and how hard the unit works matter more than the brand.
Is my Armstrong Air still under warranty?
Registered within 60 days of installation, Armstrong Air units get 10 years on parts and the compressor and a limited lifetime on heat exchangers; unregistered, 5 years and 20 years. Armstrong Air's warranty lookup checks a serial, and the term is also printed on the back of the installation manual.
How do I find the size of my Armstrong Air AC from the model number?
Look at the two digits after the region digit: in 4SCU16LE136P, 36 is the size code, about 3 tons. The 16 before the letters is the SEER.
Has Armstrong Air had recalls?
Yes. CPSC lists 1 recall since 2000 that name Armstrong Air furnaces, central air conditioners or heat pumps. Most cover specific models or build dates, so check the model and serial against each notice listed on this page.
Sources
- Building Intelligence Center
- McGarry and Madsen Home Inspection
- InterNACHI inspector forum
- Energy Trust of Oregon furnace chart
- PickHVAC
- Allied Air 4SCU16LE split system air conditioner specifications 4SCU16LE-100, 08/2023
- Allied Air Enterprises release, Aug 3 2021
- Armstrong Air: About
- Armstrong Air warranty registration
- Allied Air Enterprises equipment limited warranty W-2008-2, 2013
- Armstrong Air FAQ: what is the warranty on my unit?
- Armstrong Air warranty lookup
- CPSC: Armstrong Air and AirEase 96% gas furnaces (carbon monoxide hazard)
- EPA: What technicians and contractors need to know about phasing out HCFC refrigerants
- Contracting Business: EPA revises refrigerant rules, ends R-410A installation deadline
- NAHB: EPA finalizes refrigerant rule update to allow older HVAC unit installation
Serial rules last checked against their sources October 19, 2026. Warranty, model and recall details checked November 16, 2026. Found a date that doesn't match your label? Tell us.
Keep a record of your home
The age you just looked up is the kind of fact that gets lost. A written record of serial numbers, install dates, repairs and who did the work saves the next owner, inspector or insurer from guessing.

Keep This With the House
A lifetime logbook for the house, organized by system, with room for serial numbers, install dates, repairs and contractors.

The House Has Old Pipes
Galvanized, polybutylene, cast iron and the sewer line: what fails, what it costs and how to decide.
Book links are Amazon affiliate links.